If you follow the cooler pipe that comes out of the cylinder coil, that 1. Im not a plumber, so their may well be better options or products out there, let me know how you get on. The return is water travelling back to the boiler after going through towel rails, radiators and copper pipe work. Only needed new fan bearings once in 20 years I had it. By clicking Accept All, you consent to the use of ALL the cookies. It is really far better fited on the return otherwise all dirt from the rads flows through the boiler before hopefully being ( partly ) trapped by the Magnaclean. The cookie is a session cookies and is deleted when all the browser windows are closed. No wonder it's the UK's first-choice filter. Your MagnaClean should be serviced annually, just like your boiler. British-built, compact and lightweight, with tough brass hydraulics. 2 opinions here. Need Advice about Boiler and Central Heating Repair Please, Central Heating Return Pipe for Magna Clean, Connecting a Magna Cleanse to radiator valves, Just to say Hi and give some info about my system. You can create your listing free at DIYnot Local. MagnaClean magnetic filters can be fitted to an existing heating system, meaning that you don't need a new boiler to enjoy the benefits of one. JavaScript is disabled. site. The warranty on most of these magnetic boiler and radiator system filters vary depending on what you buy, just like the price and VAT. We show you how they work, how they use a huge magnet to attract magnetite from the heating system water, how to install one and how to use the magnaclean as a dosing pot for adding central heating inhibitor and cleaners. A lower warranty does not make the design worse, so the 10-year warranty will not always be the best available option for your system. What Is A MagnaClean Filter? Should You Have One? - iHeat Lorem ipsum dolor sit amet, consectetur i know the return is the best place, but i am in the position of it being done incorrectly. The instructions specify that the Magnaclean is installed on the return to the boiler after the last radiator and before any system filling/pressurisation point, next to the boiler was a good location for me. These potential costs don't include installation, the price of which will vary depending on the installer you hire. Fitting instructions say preferably on the return just before boiler. However, you may visit "Cookie Settings" to provide a controlled consent. MagnaCleanse is our version of a power flush. Have been asked to quote for a number of LPG boilers so if I get the job will do my LPG ticket. Your email address will not be published. Required fields are marked *. If you have an ADEY MagnaClean installed for multiple years, you could cut down maintenance for your boilers by a huge amount. This website uses cookies to provide you with a better experience. Lock red wheel against canister. The MagnaClean Pro 2 and Micro 2 have a warranty of 10 years - every other ADEY MagnaClean filter product is only 2 years as standard. CAUTION: Do NOT overtighten. Obviously, I will need to look at it more closely once we move in but at least I have a good basic Thats up to you, but might be all a plumber would do, amongst checking rads and boiler. Whether youre fitting a MagnaClean Professional2 on a brand-new boiler or retrofitting it on an existing boiler, get the installation right to give the boiler the best protection. Thread: Pressure thread. Thanks for the update, its always good to understand the approach others take to things, your boiler sounds bullet proof lol and owes you nothing which is brilliant. Adey Pro2 Magnaclean Professional 2 Magnetic Filter 22mm ( BRAND NEW ) New. No wonder its the UKs first-choice filter. These product assemblies contain valuable materials which can be recovered or recycled. Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. On my system, not a great deal. After installation, you should use MC1+ Inhibitor, a chemical liquid the dose of which should be monitored regularly, ideally during an annual service. We show you how they work, how. Engineered to actively trap virtually all circulating debris, it never stops delivering the very best protection. A copy of these can be found at http://www.hse.gov.uk/electricity Baxi 825 Combi 25KW Gas Boiler 10 Year Warranty Brand New in box and includes a compact Adey Magnaclean Micro 2 magnetic system filter to protect the heating system Cash on Collection Only 850 Saving of over 300 . ADEYs got some handy tools I assume the installer had a good reason for doing it that way.The return pipe to the boiler comes down through the ceiling into the top port of the Magnaclean, then runs from the bottom port of the Magnaclean into the top of the boiler. Magnaclean installation boards.ie - Now Ye're Talkin' Our panel of lenders will do a credit assessment of your circumstances when you apply. 25. I'm new to oil fired boilers. If you live in the Greater Manchester region, or anywhere in the North West for that matter, here at iHeat we present the simplest and quickest way to LeadsUK Ltd is authorised and regulated by the Financial Conduct Authority, A cookie set by YouTube to measure bandwidth that determines whether the user gets the new or old player interface. JavaScript is disabled. Today (21 April 18), I decided to install a Magnaclean Pro 2in my heating system which has a system boiler with hot water and central heating controlled using the S plan design. Installed a Magnaclean a year ago, at a time that I needed a replacement boiler (heat-exchanger burnt through). Necessary cookies are absolutely essential for the website to function properly. Page 4 Tighten compression nuts. A full installation could extend the lifespan of older gas boilers and brand new boilers with equal effectiveness. at the best online prices at eBay! The best way to check is to measure the pipes you are planning to attach the magnetic filter to since some homes will have a heating system with more than one pipe size. The MagnaClean DualXP has two powerful magnetic capture zones to remove greater volumes of iron oxide sludge and is the ideal solution for light commercial systems. Manage Settings Care should be taken when handling. MagnaClean Commercial | ADEY The unique, proprietary design of the MagnaClean Commercialline maximizes first-pass capture of magnetic debris by forcing system water flow past powerful magnets that 'ACTIVELY' trap any circulating iron oxide sludge, preventing potentially expensive damage to the system and its components. An example of data being processed may be a unique identifier stored in a cookie. Even over a period of only three days, this can improve your heating system dramatically. Check the system water pressure is between 1 and 1.5 bar on the system pressure gauge. The filter that connects directly to your smartphone allowing visibility of your customer's' heating systems. I contacted Adey who make the Magnaclean filter and spoke to their technical team. Cliquez sur 'CHANGEZ DE PAYS' pour accdez un site Web d'un autre pays. Could I just close this thread (maybe) with an update: You must log in or register to reply here. This also ensures a system flush can be carried out using a MagnaCleanse on the return . No pressure! During the servicing of your MagnaClean, the engineer will clean out all of the debris that's been collected by the magnet. This cookie is installed by Google Analytics. 5 May 18 Checked the Magnaclean and this is what it had caught: My Vaillant Thermocompact system was installed in 2003 and has 13 radiators piped in 10mm. Please choose the country website you wish to access, Bitte whlen Sie die Website Ihres Landes aus, auf die zugreifen mchten, Veuillez choisir le site internet du pays pour lequel vous souhaitez accder. Magnaclean Micro - flow/return direction | PlumbersForums.net As I only partially drained the system, (downstairs radiators are below the boiler so I only drained upstairs), 500ml should be sufficient to top up protection. MagnaClean Commercial for inline, full-flow system filtration - ADEY Fitting magna clean on flow | PlumbersForums.net It may not display this or other websites correctly. Magnaclean Installation Instructions: 5-Step Help Guide This is a small 22mm magnetic heating central heating filter designed to fit in hard to reach spaces and. Installer Benefits Technical Specifications Installation & Servicing Guide Homeowner Benefits Select the supplier or trade you require, enter your location to begin your search. ZU VERKAUFEN! on your requirement. Find many great new & used options and get the best deals for IDEAL LOGIC PLUS + 24/30/35KW COMBI BOILER & HORIZONTAL FLUE 7yrs warranty at the best online prices at eBay! The instructions specify that the Magnaclean is installed on the return to the boiler after the last radiator and before any system filling/pressurisation point, next to the boiler was a good location for me. All MagnaClean filters come with a warranty that will protect you should something go wrong, the length of the warranty will depend on the product you have installed. To do both, simply follow our guide. Whether you're fitting a MagnaClean Professional 2XP on a brand-new boiler or retrofitting it on an existing boiler, get the installation right to give the boiler the best protection. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. Magnaclean Pro 2 question | Screwfix Community Forum At the end of the products useful life, please leave it at an appropriate local civic waste collection point. Whether youre fitting a MagnaClean Professional 2XP on a brand-new boiler or retrofitting it on an existing boiler, get the installation right to give the boiler the best protection. The more radiators there are, the bigger the magnetite problem. You can create your listing free at DIYnot Local. The cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Functional". Magnaclean Pro 2 Installation - My Blog [1] Wireless thermostat included with all Combi Boiler installs only, [2] Full terms and conditions regarding disposal Description / Action Required. Registered in England & Wales number 6873930. Some of our partners may process your data as a part of their legitimate business interest without asking for consent. Joe Geraghty, Business Development Manager at Sweeney Rogers Geraghty Inc. To view the purposes they believe they have legitimate interest for, or to object to this data processing use the vendor list link below. Just could not get the ADEY page to load! Description / Action Required. it goes on the return to reduce the muck going into the boiler, it aint working if its on the flow then is it. Good Condition. magnaclean on flow or return - simssuccessgroup.com to help you protect your Adey Magnacleanse Central Heating Complete Solution Kit 22/28mm (206KJ) (2) 1 Year Guarantee Removes Suspended Black Iron Oxide Saves Water Was 539.99 Save 40.00 (7%) 499.99 Inc Vat Click & Collect Delivery compare Adey CP10300625 Magnetic Filter & Chemicals Pack 22mm (8350R) (6) If you are stuck, you can always get help from a professional or more information from ADEY themselves. Whether youre fitting a MagnaClean Professional2 on a brand-new boiler or retrofitting it on an existing boiler, get the installation right to give the boiler the best protection. Enter your postcode to find your nearest merchant . Fernox TF1 or Magnaclean filter? - www.ultimatehandyman.co.uk It does not stop water from getting to your radiator and does not reduce the output of your new boiler but will get sludge, rust, debris, and other blocking objects out of the way. The answer is our MagnaClean Professional2XP. Savings Calculator and FAQs. Essentially yes. As long as its accessible there is no problem fitting it under the floor! Help fitting MagnaClean needed (re location) - HomeOwnersHub When you clean a Magnaclean, a simple process, you can see it is 100% clean. We review and install the Magnaclean Atom from Adey. MagnaClean Professional2XP | ADEY 3 - Wipe filter dry. Read up on a maintenance guide if you find one, and be sure to try the simple solutions first. These cookies will be stored in your browser only with your consent. What do they achieve? The other fall-back idea I had was to install isolation valves before and after the MagnaClean to eliminate the need to use the built in valves if I had too. The ADEY Best Practice heating system protection is a six-step process using products engineered to ensure maximum efficiency in hydronic heating systems. Good job buddy. You don't say which Magnaclean filter, but if you use the Magnaclean Pro 2, it has 360 rotational valves, so can be fitted in many ways,you might over come your problem by extending the CH return with a loop for the filter, well worth while having a filter fitted. The cookie is used to store and identify a users' unique session ID for the purpose of managing user session on the website. This is the best time to get a magnetic filter installed as it will work to prevent any blockages from the first time your brand new boiler is called into action. receive commission if your application is successful and the amount may vary depending on the Awkward Fitting of Magnaclean | Screwfix Community Forum of old tanks can be found here. magnaclean on flow or return - noemiebelasic.com You don't have permission to view attachments. Electrician Talk | ElectriciansForums.net. Get a free fixed price quote for a new boiler installed fast! Honeywell 40003916-001 2-Port V4043H Replacement Powerhead 22mm 22mm Compression CMB326FV | Heating Unlike a MagnaClean, a MagnaCleanse is only fitted temporarily while the engineer clears the system of any debris. Remember that the product makes installation very easy, so many people will not need to pay for it to be installed. Snap! I understand these cleaners need to be fitted on the return. Electric Heating Company on LinkedIn: #electricheatingcompany #ehc # For a better experience, please enable JavaScript in your browser before proceeding. Believe me, the Professional2XP has made a big difference. How to clean a magnetic filter on a boiler | Viessmann UK OpenTherm interface allows operation using a smartphone or tablet. Always release pressure before servicing. products you need in a Dont think it makes that bigger deal. The installation instructions say "The bottom inlet is the flow, with the arrow pointing into the canister. event the promotional product cannot be supplied the company will offer a similar alternative. The advanced technology bridges the gap between the domestic filter range and the MagnaClean Commercial products. The valve assembly uses a slip coupling so one end has no internal pipe stop whereas the the other end has an internal stop 15mm in, this means the valve needs to slide down by 15mm before the other pipe can enter the valve assembly and then the whole thing slid up to enable the compression nuts to be fitted. With over 15 Years of experience in providing products across the UK, our wide range can assist in providing safe, lasting electric heating and infrastructure for any high-rise building whilst. Easy dosing of ADEY treatment products via canister. We may So the most logical location for this sort of filter is on the return just before the boiler. at the amount of suspended oxide it collected. Discussion in 'Plumbers' Talk' started by Mosaix, Mar 1, 2017. From the picture I can see no space to get behind the filter and close isolation valves unless one has special tools or super thin fingers.. No denying that its tight , the Magnaclean comes with two spanners, a larger one for the lid removal and a smaller one to access the valves in restricted space, this is the one I use. I can extend this to 210mm by redoing some pipework- would 180-210 mm of pipe between elbows be enough space to mount?