document.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); Professional plumber and home repairs expert, How To Remove Broken Hayward Super Pump Drain Plugs. do i need to do something different? I had a thunderstorm last night and my power went off for like 3 hours. So what would be the problem? Sometimes during power surges or lightning, these will be fused together and not come apart. Can A intermatic timer for a pool be lubricated I have duel timers for a low and high speed jandy pumpIt seems it might be a little louder on the fast speed side. I fastened it very securely. The pointer should point straight down, and you pull out on the dial, to set the correct time, aligning the current time with the pointer. You can turn the dial and then only wait a few minutes to check is the OFF tab is working. The green tripper trips the mechanism closer to the center of the dial and the gold tripper trips the mechanism towards the outer edge of the dial. It is not warped in any way. Sometimes old power wires split or short-out. Thank you. Richard, pull the mechanism out of the box by releasing the clip at the top and inspect the copper strips and pads on the rear. Karl, good question. Thank you for choosing Intermatic! Is it toast ? (For outside light timer) The one before was original to the house & I had no trouble. It was always fine before. i have an oval pool that is closed for the winter but there ha been a problem. Depends maybe on what it is getting stuck on, or what is catching the tripper, and are the motor gears still turning when it gets stuck? Luis, it will, until it is switched to OFF, or until the OFF tripper shuts it off. Hi Fred, the only thought I have is that the cord should not be unplugged to turn off the pump, instead, rotate the dial until it turns off, because I dont believe there is a switch to turn off the timer. Hi, if you have a variable speed pump, you do not need to use the external timer anymore, but should program with the on-board pump timer. This div height required for enabling the sticky sidebar. I tried to change the on tripper due to Daylight savings time & dropped the screw. If test shows that timer is not turning ON-and-OFF, then timer is bad or trippers are worn and need replacement. ft. home is a 3 bed, 4.0 bath property. But of the timer itself is bad you will need a licensed electrician to change the timer for you. I had to replace my 2 year old intermatic timer motor this season as gears werent turning. Dead as a door nail. Hi David, I suppose that you could wire the T101 from the outlet, but Im not sure if that is in accordance with code. Intermatic time clocks are the workhorse of your pool equipment collection, and oftentimes outlive the equipment they control. Welcome to Pool Spa Outpost! Either that or if an older clock, the motor may be failing, or the switch mechanism worn (the part that is tripped by the tripper). I have changed the dog tripper and that does not take care of - Answered by a verified Electrician . But no gears or any sound. I found a diagram showing neutral to A, line 1 to terminal 1 and line 2 to terminal 3. The mechanism for the off tripper doesn't work at all when manually depressed. Thanks again for your help. LIMITED TO A ONE-TIME RUN OF 666 UNITS. Breakers go bad sometimes, after many years. And Ive noticed lately that the ON is not functioning all the time. We have a comprehensive article that covers what to do when the pump circuit breaker continually trips. It could be a worn switch and/or tripper on the timeclock, struggling to switch it to on, which creates enough overload to trip the breaker. I have heard that perhaps a run of mis-marked motors went out and you may have a 50 Hz actually. i have a P1121 intermatic timer connected to a hayward above ground pool pump. Timer must be reset for current time after power outage. Here are some pictures. If your pool pump timer is beyond repair, call a professional to replace it. Or might find something else. White is usually neutral (for 115V power), and black/red are usually hot, but sometimes people dont always use the correct wire color. If the power has gone out, your just opening your swimming pool for the season or some third reason, you may need to adjust the time on your Intermatic swimming pool timer. Some of the most common issues for a pool pump timer not working are: power outage, incorrectly positioned yellow clock wheel, loose timer trippers, faulty internal timer, and a worn-out motor. Two days ago after my pool pump shut off automatically I decided to turn it back on because the pool was still dirty. March 16, 2022 by WildRiverCountry. Hi Casey, perhaps the cord or wires are broken? "headline": "Intermatic Pool Timer Troubleshooting",
Generally the power goes from the breaker > Timeclock > pump, so that the power is always on to the clock. I need to replace a timer for my pool vacuum. but ythe costs for T104 models vary greatlyHave ahayward 1 1/2 horsepower pump inground pool in Fl. "@type": "ImageObject",
please help me. Shut off the breaker and check that the wires are tight on the terminals, and that the white wires are connected well on the motor (depress the tab at the top to inspect behind the time clock). My original timer worked for 5 years then the clock stopped and I heard no sound. Miriam, I would check that the timer dogs are pushed fully onto the dial, and the dial is tight also check the screw for tightness in the center of the dial. "caption": "In The Swim Blog"
2nd black goes to -2 If youve followed this guide or arent confident in diagnosing the issue yourself, seek a qualified pool technician or electrician. Put a meter on the wires or trace them back to find out their voltage and source. Hello have a question some what related. Use Green ON tripper for T100 Series timers and the silver ON tripper is for all other models. Just moved into my house and the pool pump continues to run even after tripping the timer mechanism. This page is fantastic!! "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
That should quiet it down. it could also be a failing breaker, but that would be a last resort. I had to order new trippers as mine have been straightened too many times. Followed all directions and even watched YouTube troubleshooting videos. The most common pool timer used for inground pool pumps is the Intermatic time clock. Move the start and stop pins to appropriate times for swimming pool filter operation. This will cause issues such as the pump not switching on or off to the pump turning on or off at incorrect times. Clock not turning or making any sound. Off flipper always works. Same goes for slipping timer dogs! Push down on the timers until they snap into place. First time pool owner, Pool timer and trippers not working properly! It stays on until I turn off the circuit breaker. Switch the breaker off at the power board. Hi Chad, the trip mechanism on the clock, the switch, could be worn to the point where the tripper does not make good contact. I have replaced my pool timer 3 times in the last week and they will work for a day then quit working any idea what the problem could be? Any suggestions? Timer not tripping pump on. Started about a month ago and I checked the dog tripper at that time and it started working again for awhile but hasn't now for a week. They are: Heres how to troubleshoot a mechanical pool timer step-by-step: It goes without saying that you should be qualified if you intend on working with live power. Hi Davy, But if your circuit breaker is in the on position and your pool timer clock is not rotating and the timer is not working then you will need to call a licensed electrician to replace the timer. The pool pump can run for 16 hours every day, which means not only will you save electricity, but you also will recover the cost of the timer within 2 years. },
Hi Jerry, it could be that the lubricant is gone, or needs more lube on the switch. So if you see the 10am behind the time marker, this means that the timer has the current time of 10am. Does the manual lever stay in the on position always? The screw in the center point timer occasionally comes loose due to vibrations from the pump and filter. $115 Providence distortion MIJ - $120 All working perfectly Should be clear in photos which include boxes, others will be bubble wrapped and . Watch these tips and tricks before replacing it. One morning I noticed my pool didnt automatically turn off. If you need to set the time, you will need to take two fingers and slightly pull the wheel towards you and away from the back of the timer box. We had a few power outages the last couple of weeks, but Ive reset the time and it continues to lose time. On mine, the gears behind the dial look metal, but the motor (behind the plate) they look plastic (maybe?) },
not sure what is the problem. Also I have rotated the dial several times to trip on and off hoping that it lubricates the problem lever and dusts off the coil well. The 120V or the T101 model has 3 brass screws (terminals) underneath the plastic insulator cover. I replaced T104 timer it runs and shuts off with no issue but once off the timer does not move or turn back on. The clock will also be missing 3-hours of time, so will need to be reset to the current time. Or be loose and not making good contact. by Intermatic Technical Support | Jul 25, 2022 Helpful? Ive got a weak pump battery so every time the mechanism shuts off it looses time. Hi Cody, if you cannot see any obstruction in the motor gears, or any such mechanical issue, then I would assume an electrical issue, perhaps the wrong voltage for the clock. Since you have another switch in between the breaker and clock, the breaker will lose power when the switch is turned off. These are the trippers that came with the time clock. Any idea what may be causing this? They should be straight, if not, replace them. Because a pool timer is an electrical timer with mechanical aspects, the clock dial portion of the timer pulls out to set the time. Any ideas? Just some ideas. See the wirig diagram in the owners manual here: https://www.intheswim.com/images/PDFs/E2412_Owners_Manual.pdf Clock motor power, as shown in the wiring diagram, comes from terminal 1 and also terminal 3. It may or may not reduce the noise level however. Did somthing else maybe burnt out or what is a good troubleshooting I can do before I call an electrician. If you cant, is the manual switch stuck or jammed? Also be sure that the dial is not pulled out, but is engaging the gear behind the dial. If none of the above suggestions resolves your issues or the issues continue to persist, it may be a good idea to purchase a new Intermatic timer for your pump. Hi Mike, yes I sent you an email to your yahoo acct. However, the timer will stop around 10pm everyday and will not continue moving forward again. Yes, seen that before! Line is incoming, Load goes to the pump. Check the wire connections to be sure they are tight, and look for any burnt wires. #9. Another time clock that you can plug your pump directly into, and then plug the timer into the outlet, is the 24-hr Timer https://www.intheswim.com/p/24-hour-pump-timer (currently we are out of stock, but you can find at any home or hardware store). Hi Tanya, yes that sounds like it might be wired incorrectly, check the wiring diagram on the label, or if missing, you can find them online for your timer model. Check out the wiring diagram that comes with a new timer, or is printed on the door of the timer box. Hi, To check this, carefully inspect the gears for missing teeth and make sure they all freely turn. Should You Get a Pool Pump Timer? "dateModified": "1/10/2020",
Once you do some you will want to re-tighten the hold down screw on the timer pin so it stays in place. any suggestions about how i might avoid another situation like the above would be appreciated. I have Model T40004RTe. The problem I am having is the timer clock moves correctly, but when it gets to the ON or OFF mark it stops and does not make the switch turn ON or OFF. I am using the breaker to turn on and off the pool pump. For Sale: 2 beds, 2 baths 1152 sq. Now The ice and snow have melted and the cover is getting in deeper. To use an analog timer, you simply need to set when you want the timer to be on and off using trippers. Can I wire this timer to an outlet or should I search for another solution? There should be an off pin and an on pin. We are on our third timer. I have a sweeper set on auto on the second timer and it is working correctly. DEWENWILS Pool Pump Timer, Outdoor Smart Wi-Fi Box, Heavy Duty 40A 120-277 VAC 2HP Wireless Controller Timer for Pool, Water Heater, Compatible with Smart Phone, Alexa, Google Assistant, UL Listed. Align the bar with the current time and push it back into place. Other causes include rusted springs, insect infestation and loose timer dogs. I have removed the ON TRIPPER and turn the motor on at the pump and it never trips the GFCI. Open following links to identify timer and then add a comment.
"contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Now, Im going to order some additional timer clips. Theres power to the pump using the manual override. I have an intermatic T20004R and my timer is working because it is keeping the correct time. "@type": "Person",
Hi there, Check to be sure that the yellow time dial gear on the back is engaged with the connecting gear, and pushed all the way in. It is still moving and it will trip off but not on. You could be missing the timer pins, you could have a bad timer, you could have no power to the timer or maybe even the timer is set wrong and it really is working but your not seeing it. If thats all ok, shut off breaker and depress tab at the top, to release the mechanism from the box, and look at the copper tabs in the back. You will feel the wheel pull out about an 1/8 of an inch and then you will be able to rotate the timer wheel. There is a second switch between the breaker and the timer. If the pump comes on, you definitely have power to the timer. Once you remove the water, you can use your pool brush on a pole, to gently push the pillows back to the center. PF1202T Freeze Protection Control Parts - INYOPools.com Home Pool Parts Time Clock & Control Parts PF1202T Freeze Protection Control Free Shipping on all Orders over $49! Replace the gears if this is an issue. If you do have voltage either the timer isnt switching the power to the pump or theres an issue with the pump itself or the wiring between the pump and the timer. Wont power on pump but can hear timer clicking away. Now try to jiggle it on and off. . Power surges could be to blame. Pool pump timers can last up to 20 years, depending on the model. Gas pool heaters are one of the best additions to a pool, but they are the most high-maintenance piece of equipment on, 22,000 pool parts in stock! So just turn the adjustment hold down screw on the timer pin counter clockwise about a full turn and then you will be able to slide the on or off pin to the right time on the timer wheel. Ask Your Own Pool and Spa Question Step 1 - Check that Timer is Functional Locate the two timer pins on your timer. However, since I did that the time clock stopped working I looked at the motor visual window and nothing is moving. View community ranking In the Top 5% of largest communities on Reddit. Basically 12 real life hours equals about 14 on the timer. After a power failure the timer clock can start up backwards, mine has done this several times. Turn on / off manually work fine, but The clock gears still not moving. Could be small bugs, or dirt, or both causing the problem. I have a inground pool with T10003RT4 control panel. Its best to just write down the spots each timer is in, but remember that its a 24 hours cycle so you will need to come back within 24 hours to see if the pins moved. You will first need to adjust the time on the timer first. Please let me know if you find the solution! "publisher": {
What is the problem? Posted by 4 years ago. "@context": "https://schema.org/",
Related Reading: Should You Get a Pool Pump Timer? The problem lies where the power dies, youve probably heard that before. You should always be able to switch your pump on and off manually at the timer. I used to run the pump for 8-9 hrs a day. If the switch simply does not move side to side, it may be a bad clock, if you cannot see what is stopping it from moving. I bought a new motor for mine after 20 years and learned about this the hard way. Sometimes those are looped back to the control box. Dont know what the issue is. Hi Larry, if you can see the motor gears turning in the visual motor check, you may just need some lubrication added to the tripper mechanism. Back when I was a young technician I was taught to always look for the easy things and use all my senses. To inspect, shut off power at the breaker, and push on the clip at the top of the box, to allow the mechanism to fall forward, and then you can inspect the vertical copper bars, and see how they shift and come apart (or not), when the switch is turned to off. The on/off pins are tight and pretty new stillany thoughts? I made sure the trippers were fully inserted and tight. With power off, you could also check the tightness of the on/off switch, it may be missing the tension spring also, check that its there. If I have to tell you which terminals to measure, you shouldnt be doing this! The pool was running on a timer. Intermatic timers can typically be fixed by checking theres power to the timer, resetting the time, renewing the ON/OFF trippers and renewing the gears or timer motor. Tork pool timer dial, spins freely, not keeping Timer is not 100% identified. Report B BadOleRoss 0 LifeTime Supporter Apr 30, 2011 393 Lynchburg VA Aug 21, 2012 #8 Your timer is on a 24-hour cycle. 1. Ideally, the switch would be placed after the timeclock, not before. (usually not). Secure wire conduit to the knock out with the proper conduit connectors, and first connect the green ground wire to the green ground screw labeled GRD. Please advise. Or there could be a bad relay in the control panel, if you have ice cube style relays. Hi Jeff, it could be that the terminals in the rear of the clock mechanism are fuse-welded together, and not separating like normal, when the on/off switch is flipped. Thank you. Is it Necessary? My intermatic timer is not turning my pool pump on. What Im wanting to do is just disable the turn off/on and just keep power 24/7. Look into the visual motor check window, near the top of the timer mechanism. Electrical Monke Aug 25, 2021 #22 It's broken. Hi Rich, is one of those wires (white?) Replaced complete new timer assuming 5 years perfect service probably wore it out. If you cant see an issue with the gears, then it could be the timer motor. Check that dial is not warped. There could also be other mechanical reasons for this happening, such as a disconnect in the switch. Ive reset the time 5 times and just realized that its going counter clockwise. The pump worked perfectly before I unscrewed it. If still not working, check the wire connections and then test voltage on the clock incoming wires, outgoing wires, and then at the pump motor the problem lies, where the power dies, as they say. If not, Turn off breaker, release the mechanism with the tab on the inside top, to drop the mechanism forward. Put them back on and tighten them. Resolved! I have the pool timer with the red teeth that you pop up or down depending on when you want the pool to run. Sometimes the trippers get loose or damaged. The pool timers I have had down there . When I turned it back on now the pool clock goes backwards. Hi Peter you say that clock is seated correctly, and I assume you mean that the dial is pushed in, or the gear on the back of the dial is engaged with the turning gear. Does the tripper work on other areas of the clock, like near the off tripper? Also be careful not to loosen the timer pins to much or they could fall off the timer wheel and onto the ground. Ill do the same. "height": "219",
You will first want to look at the pool timer and see if you have two timer pins. Hello Davy, Terry here again. Thanks. And does the switch look worn, where the tripper engages? Hi Catherine, turning it on manually should not have damaged anything, so go easy on yourself It might have just been time to go. how can I turn the time bar back down to the 6 oclock point so my timer will turn the lights on some how it is in the 2 oclock position an will not turn on automatically, Your email address will not be published. http://waterheatertimer.org/Tork-timers-and-manuals.html Hi, hope you are doing well. Hi, Davy, seeing lots of complaints here. See the next section in this article for that. Any suggestions as to how to test clock feed? AJH Trade Group also participate in other affiliate programs. Recently i just notice my T104R timer a bit noisier than usual. How can it keep time if lever is in off position (manual lever). "description": "Frequently asked questions about Intermatic T104 and T101 timeclocks, used to power many loads, and the primary timer used for swimming pool pumps in America. This will disengage the dial from the . "wordCount": "1259",
The works fine and keeps time while it is on but the second it turns the filter off, it stops keeping time and the cogs stop moving.